Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Click Here to View Replacement Aquarite Parts
Things You’ll Need
Step 1
Before recalibrating, test the water with salt water test strips to determine the correct salt level. If the results from your test strip are not the same as the Aqua Rite, proceed to step 2.
Click Here to View Salt Test Strips
Step 2
With the pump running, move the main switch from "Auto" to "Off" and then back to "Auto". Wait for approximately 10 - 15 seconds for a click inside the panel.
Step 3
Once you hear the click, immediately push the Diagnostics button 5 times. The system will now begin to recalibrate.
Step 4
A number will appear on the display screen and begin to scroll down. Once the number on the screen matches the number from your test strip result, move the the main switch from "Auto" to "Super Chlorinate" and back to "Auto".
Step 5
The Hayward Aqua Rite should now be successfully recalibrated. If the incorrect salt reading continues to be a problem, it may be time to replace the salt cell.
Click Here to View Replacement Aquarite Parts